Cleaning of bridges 

 

 

 

Photos:

 

 

 

               

 

Technical data:

 

Surface: steel
Contamination: corrosion and paint
Thickness of contamination: different
Remarks:

non

 
Air pressure: 12 bar
Air flow: 10m³/ min
Water consumption: 100 liter per hour
Abrasive additions: soda
Nozzle: G2
Result: 10 - 15 m2 per hour, depending on the type of soda and form of corrosion.